CALIBRATOR
 
   Pressure Comparator -

FEATURES  : 

  • Rugged and highly accurate.
  • Digital Readout.
  • Easy to Operate.
 
   SPECIFICATION : TYPE   DATA

Maximum Pressure Generation 10,000 psig or 700 barg.
Optional Digital Gauge Range 100, 300, 500, 1000, 2000, 3000, 5000, 1000 psig.
Pressure Connection ¼”, 3/8”, ½” BSP Female.
Compatibility Distilled Water / Hydraulic Oil.
Material Brass, Nickel Plated.
     
     
Level
Pressure
Temperature
Digital Indicator
Recorder
Calibrator
I/P Converter
Portable Measuring Instrument
Humidity
Gas Detectors ans Analysers
Safety Switches for Material Handling
   Digital Pressure Calibrator -

FEATURES  : 

  • A Versatile Range of Application.
  • Measurement in the area of relative, differential or absolute pressure.
  • Also available in Ex Version meets all requirements for application in hazardous areas.
  • PC Communication is possible.
     
   SPECIFICATION : TYPE   DATA

Range 0 -  700 bar.
Units of Measurement mbar, bar, Pa, hPa, kPa, MPa, Kg/Cm², Kg/m², mmHg, cmHg, mHg, inHg, mmH2O, cmH2O, mH2O, inH2O, ftH2O, psi, lb/in2, lb/ft2, torr, atm.
Temperature Calibration 0 – 50 ˚C
Power Supply 3 x 1.5 V battery
     
     
   Huminator (Humidity Generator) -

FEATURES  :

  • Fast and Easy Humidity Calibration of Measuring Instruments, Probes and Data Loggers
  • Can be programmed individually.
  • Uer Friendly.
  • RS- 232 interface.
     
   SPECIFICATION : TYPE   DATA

Measuring Range +15 to +40˚ C / +5 to +95%  RH.
Accuracy 0.5˚ C
Power Supply 85 to 264 V AC, 47 to 63 Hz.
Connection RS- 232 interface.
     
     
   Mini wind Tunnel -

FEATURES  : Compact and User Friendly.

     
   SPECIFICATION : TYPE   DATA

Velocity  2.5 / 5/ 10 m/s, can be switched.
Length 610 mm.
Range of Application +10 to +40˚ C
Motor Direct Current Fan.
Power Supply 230 V / 50 Hz or 110 V can be switched.
     
     
   Temperature Bath -

FEATURES  : 

  • Dry Block Type.
  • Micro Controller based for higher accuracy.
  • Interchangeability Inserts for different size of Sensors.
  • Multi- hole insertion tube can be supplied as per requirement.
  • Simultaneous display of both set points and process variable.
  • Calibration Certificate from Govt. approved laboratory.
     
   SPECIFICATION : TYPE   DATA
Range Ambient to 1200˚ C.
Accuracy  ± 1.0 to 3˚ C.
Well dia 25 mm.
Well depth 120 mm.
Supply 220 V, 50 Hz
Communication RS 232
     
     
   Universal Calibrator -

FEATURES  :

  • Hand held, Battery Operated, Portable.
  • Pt 100 reading directly in terms of Temperature.
  • Independent Calibration facility for mV, mA, Ohms, Temp.
  • Typical Accuracy 0.1% ± 1 digit.
  • Operation battery eliminator for operation on 230V AC.
  • Operational Portable Loop Power supply for 2 Wire Transmitter Calibration.
     
   SPECIFICATION : TYPE   DATA

Power Supply Two Batteries of 9V, Size PP3 (Optional) Battery Eliminator for 230 V AC Operation
Indication 4½ digit LCD display with battery low, over range & Polarityc Indication.
Operating Temp. 0 to 50˚ C.
Humidity Max. 90% Rh Non Condensing.
Storage Temperature 0 to 70˚ C.
Source / Sink mV, mA, Ohms, Temp
   
Powered by : calcuttayellowpages.com Home About Us Photo Gallery Clients Contact Us Feedback