Digital Process Indicator
   
 
  1. DIGITAL PROCESS INDICATOR / CONTROLLER
  2. DIGITAL PROCESS SCANNER
  3. DATA LOGGERS
  4. SINGAL ISOLATORS / CONVERTERS / MULTIPLIER
  5. PID CONTROLLER
  6. BAR GRAPH INDICATOR
 
   Digital Process Indicator / Controller -

FEATURES  : 

  • Microcontroller based, Fully Programmable.
  • Universal / Dedicated Input.
  • Programmable Setpoints.
  • Isolated Retransmission.
  • Built- in two wire transmitter supply.
  • Field Calibration from front key pad.
  • Available in various Cutouts and sizes.

APPLICATION  :  For Indication of various Process Parameters.

Specification
TYPE   DATA
Input 0 / 4 – 20 mA DC, 0 / 1 – 5 V DC.
RTD Pt- 100 3 Wire, Thermocouple (J, K, R, S, T, B) Display 4½ digit LED
Output Relays 1 NO + 1 NC Per Set Point, Rated at 230 V AC, 5A Resistive load.
Transmitter Power Supply 24 V DC, 30 mA
Retransmission Output 4 to 20 mA (Isolated).
Programming All parameters programmable by front key pad.
Supply 230 V AC, 50 Hz.
Mouting Flush on panel.
Dimensions (Cutout) 92 x 92 mm / 138 mm x 68 mm / 92 mm x 45mm.
top
   Digital Process Scanner -

FEATURES  :

  • Universal Input
  • Serial Port RS 232 or RS 485 Port with MODBUS RTU Protocol.
  • Channel  Skip Facility
  • Fully programmable from front key pad.
  • Individual Set- Points programmable for each channel.
SPECIFICATION :
TYPE   DATA
Input 0 / 4 – 20 mA DC, 0 / 1 – 5 V DC. RTD Pt- 100 3 Wire, Thermocouple (J, K, R, S, T, B)
Range Calibrated as per customer requirement from front key pad.
Display 1) 4 digit, ½” red LED for Process Value.
2) 2 digit, ½” red LED for Channel Number.
Modes Auto / Manual.
Display Update Time Programmable from 2 Sec. to 30 Sec.
Set Points Two Nos. programmable for each channel (optional)
Output Relays 4 Relays, 1 NO + 1 NC Per relay common for all channel, Rated at 230 V AC, 5 A Resistive load.
Alarm Indication Provided by individual LED’s on front.
Retransmission Output 4 to 20 mA (Isolated)
Programming  All parameters programmable by front key pad.
Supply 230 V AC, 50 Hz.
Mouting Flush on panel
Dimensions (Cutout) 138 mm x 68 mm
top
   Data Loggers -

 

 

Input : RTD, TC, Humidity Sensors.
No. of Channels : 4.
Data transfer to PC.

top
   Singal Isolators / Converters / Multiplier -

FEATURES  : 

  • Wide range of mV, TC, RTD, Current, Voltage, Slide Wire Transmitters and Alarm.
  • Upto four Isolated Outputs.
  • Three Port Isolation provided (between input, output and power supply)
  • Front panel access for span, zero and set- point adjustments.
  • Single or dual set- point for alarm trip module.
  • DIN Rail, back of panel mounting.
SPECIFICATION :
TYPE   DATA
Input 0 / 4 – 20 mA DC, 0 / 1 – 5 V DC. RTD Pt- 100 3 Wire, Thermocouple (J, K, R, S, T, B)
Output    1) 4 – 20 mA DC, 2) 0/1 to 5 V DC, 3) 0/2 to10 V DC.
No. of Outputs  Upto 4 Nos. Provided.
Alarm Contacts 2 NO + 2 NC Potential- free contacts rated at  230V AC, 5 A resistive.
Isolation > 100 M Ohms at 500 V DC.
Transmitter Supply 24 V DC, 30 mA for powering two wire transmitter.
Accuracy  < ± 0.2% of FSD
Supply  230 V AC, 50 Hz.
Mounting DIN Rail / Back of panel.
Dimension 1) 56 mm (W) x 120 mm (D) x 132.5 mm (H)
2) 20 mm (W) x 140 mm (D) x 132.5 mm (H)
3) 60 mm (W) x 110 mm (D) x 70 mm (H)
Operating Temp. 0 to 50˚ C
top
    PID Controller -

FEATURES  : 

  • Minimum Start up Overshoot.
  • Ultra Stable Straight line Control.
  • Quickest Disturbance Recovery.

SPECIFICATION :

TYPE   DATA

Input Universal, 0 / 4 – 20 mA DC, 0 / 1 – 5 V DC.
RTD Pt- 100 3 Wire, Thermocouple (J, K, R, S, T, B) Accuracy ± 0.25% of reading,  ± 1 LSD,  ± 1˚ C.
Measuring Rate 5 Samples per Second (Sampling time 200 mS)
Ramp / Soak Built- in
Output Upto 3 Output.  Universal, User Selectable.
Communication Possible.
Supply Voltage 85 to 264 V AC, 50 / 60 Hz.
top
    BAR Graph Indicator -

FEATURES  :

  • Microprocessor Based Fully Programmable.
  • Graphical / Digital Process Parameters Indication.
  • Single / Dual Channel.
  • Universal Input.
  • Isolated Retransmission Output.
  • Built- in Auto Manual Operation.
SPECIFICATION : TYPE   DATA

Input 0 / 4 – 20 mA DC, 0 / 1 – 5 V DC. RTD Pt- 100 3 Wire, Thermocouple (J, K, R, S, T, B)
Range  Calibrated as per requirement from front key pad.
Display 1) 51 Segment LED bargraph x 2 Nos.
2) 4 digits, 0.3” red LED x 1 No. or 2 Nos. for digital read- out.
Output Relays 2 Relays Per channel, 1 NO + 1 NC per relay, Rated at 230 V AC, 5 A Resistive load.
Retransmission Output 4 to 20 mA x 2 Nos. (Isolated).
Programming All parameters programmable by front key pad.
Communication Port RS 232 or RS 485 with MODBUS RTU (Optional)
Supply 230 V AC, 50 Hz.
Mouting Flush on panel
Dimensions (Cutout) 92 x 92 mm / 138 mm x 68 mm.
Operating Temperature 0 to 50˚ C
Humidity 90% maximum
top
 
Products Pressure | Temperature | Level | Flow | Humidity & Dew Point | Digital Process Indicator | Data Logger & Recorder | Calibration Equipments | I/P Converter, Precision Regulators | Portable Measuring Instruments | Gas Detector & Analyzers | Safety Switches for Material Handling | Laboratory Instruments